{"product_id":"mira-safety-nbc-77-sof-filter","title":"MIRA Safety NBC-77 SOF Filter","description":"\u003cdiv\u003e\n                \u003cdiv\u003e\n                \u003c\/div\u003e\n                \u003cp\u003eThe MIRA Safety NBC-77 SOF Gas Mask Filter in combination with a full-face respirator, mouthpiece assembly, or PAPR, reliably protects air passages from a wide range of harmful and highly toxic substances, including all known chemical, biological, radiological, and nuclear (CBRN) agents\u003cbr\u003e\u003cbr\u003eThese gas mask filters are produced with standard round threads according to STANAG 4155 (EN 148-1) - Rd 40 x 1\/7\". The filter components are made of hard plastic. This results in a very robust product that is extremely durable against shock and impact damage in operational use.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eCompatible with standard 40mm NATO threaded respirators, which are widely available.\u003c\/li\u003e \u003cli\u003e20-year shelf life - save money long-term by not having to replace your filters every 5 years\u003c\/li\u003e \u003cli\u003eUsed by military personnel, CBRN specialists, and special operations forces all over the world\u003c\/li\u003e \u003cli\u003eFilter all known CBRN agents, including radioactive iodine, rated for A2B2E2K2HgSXP3 D R.\u003c\/li\u003e \u003cli\u003eCertified by European agencies and has the \"CE\" symbol. Compliant under EN 14387:2004 + A1:2008\u003c\/li\u003e \u003c\/ul\u003e \u003ctable border=\"1\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003cth scope=\"col\" colspan=\"2\"\u003eTechnical Data\u003c\/th\u003e\n\u003cth scope=\"col\" colspan=\"2\"\u003eBreathing Resistance In Pa\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDiameter\u003c\/td\u003e \u003ctd\u003e110 mm\u003c\/td\u003e \u003ctd scope=\"row\" rowspan=\"4\"\u003e@ Flow Rate 301\/Min. EN 1) NBC-77 SOF\u003cbr\u003e260 \u0026lt;140\u003c\/td\u003e \u003ctd scope=\"row\" rowspan=\"4\"\u003e@ Flow Rate 951\/Min. EN 1) NBC-77 SOF\u003cbr\u003e980 \u0026lt;600\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHeight\u003c\/td\u003e \u003ctd\u003e85 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e335 g ±5%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Time\u003c\/td\u003e \u003ctd\u003e20 years (factory sealed)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e \u003ctable border=\"1\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003cth scope=\"col\" colspan=\"2\"\u003eType \u0026amp; Class Particle Filter Efficiency @ Flow Rate 95 L\/M\u003c\/th\u003e\n\u003cth scope=\"col\" colspan=\"3\"\u003eParticle Efficiency @ Flow Rate 95L\/M\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eA2 - organic gases and vapors\u003c\/td\u003e \u003ctd\u003eSX - CG, CK, PS\u003c\/td\u003e \u003ctd scope=\"row\" rowspan=\"5\"\u003eSodium Chloride NaCl (S)\u003cbr\u003eParaffin oil (L)\u003c\/td\u003e \u003ctd scope=\"row\" rowspan=\"5\"\u003eEN 99.95\u003cbr\u003e99.95\u003c\/td\u003e \u003ctd scope=\"row\" rowspan=\"5\"\u003eNBC-77 SOF \u0026gt; 99.999\u003cbr\u003e\u0026gt;99.999\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eB2 - inorganic gases and vapors\u003c\/td\u003e \u003ctd\u003eP3 - particles\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eE2 - acid gases and vapors\u003c\/td\u003e \u003ctd\u003eD - dust\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eK2 - ammonia and amines\u003c\/td\u003e \u003ctd\u003eR - reusable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHg - mercury vapors\u003c\/td\u003e \u003ctd\u003eREACTOR - radioactive iodine\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic - diphenyldichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.\u003c\/p\u003e \u003ctable border=\"1\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003cth\u003eTesting Gas\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eConcentration Of Gas (PPM)\u003c\/th\u003e\n\u003cth\u003eConcentration Of Gas (MG\/1)\u003c\/th\u003e\n\u003cth\u003eBreakthrough Time In Minutes EN\u003c\/th\u003e\n\u003cth\u003eNBC-77 SOF\u003c\/th\u003e\n\u003cth\u003eDAC In Grams NBC-77SOF\u003c\/th\u003e\n\u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eA2\u003c\/td\u003e \u003ctd\u003eCyclohexane\u003c\/td\u003e \u003ctd\u003eC₆H₁₂\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e17.5\u003c\/td\u003e \u003ctd\u003e35\u003c\/td\u003e \u003ctd\u003e39\u003c\/td\u003e \u003ctd\u003e20.475\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eB2\u003c\/td\u003e \u003ctd\u003eChlorine\u003c\/td\u003e \u003ctd\u003eCl₂\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e15\u003c\/td\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003e45\u003c\/td\u003e \u003ctd\u003e20.250\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eHydrogen Sulphide\u003c\/td\u003e \u003ctd\u003eH₂S\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e7.1\u003c\/td\u003e \u003ctd\u003e40\u003c\/td\u003e \u003ctd\u003e\u0026gt;80\u003c\/td\u003e \u003ctd\u003e\u0026gt;17.400\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eHydrogen Cyanide\u003c\/td\u003e \u003ctd\u003eHCN\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e5.6\u003c\/td\u003e \u003ctd\u003e25\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003ctd\u003e8.400\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eE2\u003c\/td\u003e \u003ctd\u003eSulphur Dioxide\u003c\/td\u003e \u003ctd\u003eSO₂\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e13.3\u003c\/td\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003e25\u003c\/td\u003e \u003ctd\u003e9.975\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eK2\u003c\/td\u003e \u003ctd\u003eAmmonia\u003c\/td\u003e \u003ctd\u003eNH₃\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e3.5\u003c\/td\u003e \u003ctd\u003e40\u003c\/td\u003e \u003ctd\u003e50\u003c\/td\u003e \u003ctd\u003e5.250\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHg\u003c\/td\u003e \u003ctd\u003eMercury\u003c\/td\u003e \u003ctd\u003eHg\u003c\/td\u003e \u003ctd\u003e-----\u003c\/td\u003e \u003ctd\u003e13 mg\/m³\u003c\/td\u003e \u003ctd\u003e100 hours\u003c\/td\u003e \u003ctd\u003e\u0026gt;170 hours\u003c\/td\u003e \u003ctd\u003e\u0026gt;3.900\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSX\u003c\/td\u003e \u003ctd\u003eCyanogen chloride\u003c\/td\u003e \u003ctd\u003eCICN\u003c\/td\u003e \u003ctd\u003e2500\u003c\/td\u003e \u003ctd\u003e6.28\u003c\/td\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003e25\u003c\/td\u003e \u003ctd\u003e4.710\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003eChloropicrin\u003c\/td\u003e \u003ctd\u003eCCI₃NO₃\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e33.55\u003c\/td\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003e44\u003c\/td\u003e \u003ctd\u003e44.286\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003c\/td\u003e \u003ctd\u003ePhosgene\u003c\/td\u003e \u003ctd\u003eCOCl₃\u003c\/td\u003e \u003ctd\u003e5000\u003c\/td\u003e \u003ctd\u003e20.24\u003c\/td\u003e \u003ctd\u003e20\u003c\/td\u003e \u003ctd\u003e\u0026gt;77\u003c\/td\u003e \u003ctd\u003e\u0026gt;47.058\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eREACTOR\u003c\/td\u003e \u003ctd\u003eMethyloidide₁₃₁\u003c\/td\u003e \u003ctd\u003eCH₃I\u003c\/td\u003e \u003ctd\u003e-\u003c\/td\u003e \u003ctd\u003e-\u003c\/td\u003e \u003ctd\u003e2 Hours\u003c\/td\u003e \u003ctd\u003e\u0026gt;2 Hours\u003c\/td\u003e \u003ctd\u003e-\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eLifetime:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eBreakthrough time of a filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l\/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eStorage \u0026amp; Maintenance:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe filters are sealed in plastic bags by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDisposal:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eAfter use, the filters are special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.\u003c\/p\u003e\n                \u003cdiv\u003e\n                    \u003cdiv\u003e\n                        \u003ci\u003e\u003c\/i\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv\u003eWARNING: This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.\u003c\/div\u003e\n                \u003c\/div\u003e\n            \u003c\/div\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":53847480828272,"sku":"NBC77SOF","price":55.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1018\/6532\/4912\/files\/mira-safety-nbc-77-sof-filter-nbc77sof__15753.1601533221.jpg?v=1780035553","url":"https:\/\/tactsquadshop.com\/products\/mira-safety-nbc-77-sof-filter","provider":"Tactsquad Shop","version":"1.0","type":"link"}